USE ONLINE UPS 3.7 (0.9) P.F IN KARACHI
IGBT inverter design
Sine wave Pulse Width Modulation (SPWM)
Output less than 3% T.H.D.
Expandable battery run time
Advanced Battery Management (ABM)
Automatically charging in UPS off mode
Smart RS-232 communication port
SNMP management capability
Load and battery capacity power meter display
Specification
Specification
MODEL ONL-3750 (S/LCD) ONL-6250 (S/LCD)
CAPACITY 3.75KVA 6.25KVA
3KW 5KW
INPUT
Voltage 110V-level system: 82.5V to 137.5V
220V-level system: 165V to 275V
Frequency 50Hz / 60Hz ±5Hz auto sensing
Phase Single phase
OUTPUT
Phase Single phase
Power factor 0.8 to 1.0 lagging
Overload protection
BATTERY
Type Sealed, maintenance-free lead acid battery
DC voltage 192V
Typical recharge
time 8 hours to 90% after fully discharged
Backup time (50%
load) 29 minutes 15 minutes
Backup time (100%
load) 12 minutes 5 minutes
Protection Battery low cut-off without draining any current
S.T.S.
Power failure 0ms
Recovery 0ms
Overload disappear Auto transfer to UPS
UPS to bypass 0ms
Bypass to UPS 0ms
COMMUNICATION
Dry contact Sends AC failure and battery low signals, and receives shutdown
signal from control
RS-232 Detect power failure, battery low, schedule UPS power on/off, AC
power status display
Optional item SNMP, Novell, Windows NT
GENERAL
Dimension (W x D x
H) 265mm x 641mm x 750mm
Product weight 111.4kg 83.8kg
Display (LED/LCD)
LED - line input (green), inverter output (green), bypass (yellow), fault
(red)
LCD - indicate line, bypass, inverter, backup, fault, battery capacity,
load capacity, I/P and O/P voltage and frequency, internal temp, fault
status
Audible noise < 55dBA (1m from surface)
Communication Interface
Sine wave Pulse Width Modulation (SPWM)
Output less than 3% T.H.D.
Expandable battery run time
Advanced Battery Management (ABM)
Automatically charging in UPS off mode
Smart RS-232 communication port
SNMP management capability
Load and battery capacity power meter display
Specification
Specification
MODEL ONL-3750 (S/LCD) ONL-6250 (S/LCD)
CAPACITY 3.75KVA 6.25KVA
3KW 5KW
INPUT
Voltage 110V-level system: 82.5V to 137.5V
220V-level system: 165V to 275V
Frequency 50Hz / 60Hz ±5Hz auto sensing
Phase Single phase
OUTPUT
Phase Single phase
Power factor 0.8 to 1.0 lagging
Overload protection
BATTERY
Type Sealed, maintenance-free lead acid battery
DC voltage 192V
Typical recharge
time 8 hours to 90% after fully discharged
Backup time (50%
load) 29 minutes 15 minutes
Backup time (100%
load) 12 minutes 5 minutes
Protection Battery low cut-off without draining any current
S.T.S.
Power failure 0ms
Recovery 0ms
Overload disappear Auto transfer to UPS
UPS to bypass 0ms
Bypass to UPS 0ms
COMMUNICATION
Dry contact Sends AC failure and battery low signals, and receives shutdown
signal from control
RS-232 Detect power failure, battery low, schedule UPS power on/off, AC
power status display
Optional item SNMP, Novell, Windows NT
GENERAL
Dimension (W x D x
H) 265mm x 641mm x 750mm
Product weight 111.4kg 83.8kg
Display (LED/LCD)
LED - line input (green), inverter output (green), bypass (yellow), fault
(red)
LCD - indicate line, bypass, inverter, backup, fault, battery capacity,
load capacity, I/P and O/P voltage and frequency, internal temp, fault
status
Audible noise < 55dBA (1m from surface)