-
loading
Ads with pictures

Electrical rotary rack


Top sales list electrical rotary rack

Pakistan
​MS5900 MASTECH Determine the Motor Connection Non-Contact Rotary Field Indication Determine Rotary Field Direction Standalone direction indicator Wireless Specifications Operating Temperature: 0 °C ~ 40 °C Operating Altitude: 2000 m Pollution Degree: 2 Type of Protection: IP 40 Humidity 15 % to 80 % Electrical Safety: Meets DIN VDE 0411, IEC 61010 DIN, VDE 0413-7, EN 61557-7, IEC 61557-7 Maximum Operating Voltage (Ume): 400 V AC for all ranges Protection Level: CAT III, 600 V Battery: 6F22/9V (Not Included) Current Consomption: max 20 mA Nominal Voltage Rotary Direction: 1 to 400 V AC Nominal Voltage Phase Indication: 120 to 400 V AC Frequency Range (fn): 2 to 400 Hz Test Currents (In per phase): less than 3.5 mA Frequency Range (fn): 2 to 400 Hz Determine the Motor Connection Nominal Test Voltage (Ume): 1 to 400 V AC Nominal Test Currents (In per phase): less than 3.5 mA Shipping All Across Pakistan COMPANY: MATRIX ELECTRONICS CONTACT PERSON: FAIZAN MUNIR Mobile:03002785860 Email : sales@matrixelectronic.com Email : info@matrixelectronic.com www.matrixelectronic.com
Free
See product
Pakistan (All cities)
Description: Details iShopping.pk brings you the best price for TP-Link 16-Port Gigabit Easy Smart PoE Switch with 8-Port PoE+ (TL-SG1016PE) with express shipping all over Pakistan   Features: • 16 10/100/1000Mbps RJ45 ports • Equipped with 8 PoE+ supported ports to transfer data and power over a single cable • With a total PoE power budget of 110W, up to 30W per port • Works with IEEE 802.3af/at compliant devices, expanding home and office networks • Simple network set-up on top of plug-and-play connectivity  • Web-based user interface and management utility simplify configuration    Specification: HARDWARE FEATURES Standards and Protocols IEEE 802.3, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3x, IEEE 802.1q, IEEE 802.1p Interface 16 10/100/1000Mbps RJ45 Ports AUTO Negotiation/AUTO MDI/MDIX  Network Media 10BASE-T: UTP category 3, 4, 5 cable (maximum 100m) EIA/TIA-568 100Ω STP (maximum 100m) 100BASE-TX: UTP category 5, 5e cable (maximum 100m) EIA/TIA-568 100Ω STP (maximum 100m) 1000BASE-T: UTP category 5, 5e, 6 or above cable (maximum 100m) EIA/TIA-568 100Ω STP (maximum 100m)  Fan Quantity 1 Power Supply 100-240VAC, 50/60Hz Power Consumption Maximum: 124.4W (220V/50Hz) PoE Ports (RJ45) Standard: 802.3 at compliant PoE Ports: Port 1- Port 8 PoE Power Budget: 110W Dimensions (W x D x H) 11.6*7.1*1.7 in. (294*180*44 mm) PERFORMANCE Switching Capacity 32Gbps Packet Forwarding Rate 23.8Mbps MAC Address Table 8K Packet Buffer Memory 4.1Mbit Jumbo Frame 9KB SOFTWARE FEATURES Quality of Service Support Port-Based/802.1p/DSCP priority Support 4 priority queues Rate Limit Storm Control L2 Features IGMP Snooping V1/V2/V3 Link Aggregation Port Mirroring Cable Diagnostics Loop Prevention VLAN Supports up to 128 VLANs simultaneously (out of 4K VLAN IDs) MTU/Port/Tag VLAN Management Web-based GUI Easy Smart Configuration Utility Transmission Method Store-And-Forward OTHERS Certification FCC, CE, RoHS Package Contents TL-SG1016PE Power Cord Installation Guide Resource CD Rackmount Kit Rubber Feet System Requirements Microsoft® Windows® for running Utility Environment Operating Temperature: 0℃~40℃ (32℉~104℉) Storage Temperature: -40℃~70℃ (-40℉~158℉) Operating Humidity: 10%~90% non-condensing Storage Humidity: 5%~90% non-condensing   What This Product Does The TL-SG1016PE is an 16-Port Gigabit Desktop/Rack mountable Switch with 8 ports supporting the PoE+ standard. It provides a simple way to expand a wired network by transferring power and data over a single Ethernet Cable. With a total power budget of 110W, up to 30W per port, TL-SG1016PE can power more high-powered devices such as wireless Access Points (APs), IP Cameras or IP Phones. Moreover, with innovative energy-efficient technology, the TL-SG1016PE can save up to 75% of the power consumption, making it an eco-friendly solution for your business network. How This Product Works 8 ports of TL-SG1016PE support Power over Ethernet Plus (PoE+) standard which can automatically detect and supply power to any IEEE 802.3af/at compliant device(s). In this situation, the electrical power is transmitted along with data in a single cable, allowing you to expand your network where there are electrical cables or outlets, where you wish to fix devices such as APs, IP Cameras or IP Phones. Overload Arrangement TL-SG1016PE has a priority function which helps protect the system when its power is overloaded. If all PoE+ devices’ power consumption is greater than or equal to 110W, a priority will be arranged among the 16 PoE+ ports, at which point the system will cut off the power of the lowest-priority port.   Port Priority Function *Priority (port 1>port 2>port 3>port 4> port 5>port 6>port 7>port 8): This function will help protect the system if the system power becomes overloaded. For example, Port 1, 2, 3, 4, and 5 are using 30w (maximum power per port is 30W), the system power is 110w in total (PoE max LED will be green if all PoE PDs power consumption is >= 110W). If there is an additional PD inserted to Port 4 with 20w then the system will cut off Port 5 to protect the system, this means Port 1, 2,3, will use 90w, and Port 4 will use 20w, and no power will be supplied to Port 5. Easy To Use TL-SG1016PE is easy to install and use. It requires no configuration or installation. With its Desktop/Rack mountable design, outstanding performance and quality, the TP-LINK TL-SG1016PE 16-Port Gigabit Desktop/Rack mountable Switch with 8-Port PoE is a great choice for expanding your home or office network.  
See product
Pakistan (All cities)
Description: Details iShopping.pk brings you the best price for TP-Link 8-Port Gigabit Desktop/Rackmount Switch with PoE+ (TL-SG1008PE) with express shipping all over Pakistan.   Features: • 8 10/100/1000Mbps RJ45 ports •  Equipped with 8 PoE+ supported ports to transfer data and power over a single cable •  Works with IEEE 802.3af/at compliant devices, expanding home and office networks •  Innovative energy-efficient technology reduces power output by up to 75% •  Plug and play design, no configuration required • Equipped with 8 PoE+ ports • Supports PoE+ standard with total power budget of 124W and up to 30W per port • Supports PoE+ IEEE 802.3af/at compliant devices • Supports IEEE 802.3x flow control for Full-duplex Mode and backpressure for Half-duplex Mode • 8K entry MAC address table of the TL-SG1008PE with auto-learning and auto-aging • LED indicators to monitoring power, link, activity and speed • Internal power supply   Specification: HARDWARE Interface 8 10/100/1000Mbps RJ45 Ports AUTO Negotiation/AUTO MDI/MDIX Network Media 10BASE-T: UTP category 3, 4, 5 cable (maximum 100m) EIA/TIA-568 100Ω STP (maximum 100m) 100BASE-TX: UTP category 5, 5e cable (maximum 100m) EIA/TIA-568 100Ω STP (maximum 100m) 1000BASE-T: UTP category 5, 5e, 6 or above cable (maximum 100m) EIA/TIA-568 100Ω STP (maximum 100m) Fan Quantity 1 Power Supply 100-240VAC, 50/60Hz Power Consumption Maximum (PoE on): 133.8W (220V/50Hz) Maximum (PoE off): 9.8W (220V/50Hz) PoE+ Ports(RJ45) Standard: 802.3at/af compliant PoE+ Ports: 8 Ports Power Supply: 124W Backbound Bandwidth 16Gbps Mac Address Table 8K Buffer Size 2Mbits Dimensions (W x D x H) 11.6*7.1*1.7 in. (294*180*44 mm) SOFTWARE Advanced Features Compatible With IEEE 802.3af/at Compliant PDs Priority Function Mac Address Auto-Learning And Auto-Aging IEEE802.3x Flow Control For Full-Duplex Mode And Backpressure For Half-Duplex Mode Transfer Method Store-And-Forward OTHERS Certification FCC, CE, RoHS Consumption 9.5 watts (max. no PD connected) 140.1 watts (max. with 124w PD connected) Environment Operating Temperature: 0℃~40℃ (32℉~104℉) Storage Temperature: -40℃~70℃ (-40℉~158℉) Operating Humidity: 10%~90% non-condensing Storage Humidity: 5%~90% non-condensing   What This Product Does The TL-SG1008PE is an 8-Port Gigabit Desktop/Rack mountable Switch with all 8 ports supporting the PoE+ standard. It provides a simple way to expand a wired network by transferring power and data over a single Ethernet Cable. With a total power budget of 124W, up to 30W per port, TL-SG1008PE can power more high-powered devices such as wireless Access Points (APs), IP Cameras or IP Phones. Moreover, with innovative energy-efficient technology, the TL-SG1008PE can save up to 75% of the power consumption, making it an eco-friendly solution for your business network.   How This Product Works All 8 ports of TL-SG1008PE support Power over Ethernet Plus (PoE+) standard which can automatically detect and supply power to any IEEE 802.3af/at compliant device(s). In this situation, the electrical power is transmitted along with data in a single cable, allowing you to expand your network where there are electrical cables or outlets, where you wish to fix devices such as APs, IP Cameras or IP Phones.   Overload Arrangement TL-SG1008PE has a priority function which helps protect the system when its power is overloaded. If all PoE+ devices’ power consumption is greater than or equal to 124W, a priority will be arranged among the 8 PoE+ ports, at which point the system will cut off the power of the lowest-priority port.     Port Priority Function *Priority (port 1 > port 2 > port 3 > port 4 > port 5 > port 6 > port F > port 8): This function helps protect the system if the power becomes overloaded. For example, if port 1, 2, 4 and 7 are using 30W (maximum power per port is 30W, the system power is 120W in total), and there is an additional device inserted into Port 3 at 25W, the system will cut off the power of Port 7 in response to the power exceeding the 120W limit., This means Port 1, 2 and 4 will use 30W, and Port 3 will use 25W, with no power will be supplied to Port 7 as it has the lowest designated priority among the ports in use.    Easy To Use TL-SG1008PE is easy to install and use. It requires no configuration or installation. With its Desktop/Rack mountable design, outstanding performance and quality, the TP-LINK TL-SG1008PE 8-Port Gigabit Desktop/Rack mountable Switch with 8-Port PoE is a great choice for expanding your home or office network.
See product
Pakistan (All cities)
Description: Details iShopping.pk brings you the best price for Bosch CCS-CU Control Unit For CCS 900 Ultro Conference System with express shipping all over Pakistan.   The Bosch CCS-CU Control Unit is the central power and control station for all CCS 900 Ultro Conference System contributor units, such as the chairman and delegate units. The control unit will supply power for up to 50 delegate / chairman units, and provide control for up to 150. The unit features a built in speaker and automated, programmable control over contributor units without the need for an operator. Its Digital Acoustic Feedback Suppression (DAFS) eliminates feedback howling and maintains clear, intelligible speech. Plenty of connections allow for interfacing within paging systems, amplifier systems, recording devices and more. The unit is feature rich, however its control section is straightforward and intuitive to operate in any conference setting.   Features: Discussion Control Without Operator The CU can be setup to operate standalone without the need for an operator. The following 5 modes can be chosen using a rotary control on the unit's top panel: • Open mode - allows selection of one to four microphones (excluded chairmen microphones) which can be simultaneously active • Open mode with auto-switch-off - allows selection of one to four microphones (excluded chairmen microphones) which can be simultaneously active. If the delegate does not speak for 30 seconds, microphones are automatically switched off • Override mode - delegates can override each other simply by activating their microphones. Only one microphone can be active at any one time. (Note: In override mode, delegates cannot override chairmen) • Chairman only mode - only chairmen can speak. Delegate microphones cannot be activated, even when a chairman is not speaking • Test mode - checks if system connections are correct. All microphone light rings and contribution unit LEDs light up to indicate that units are properly connected Supplies Power for up to 50 Contribution Units The CU has two trunk outputs for the loop-through connection of contribution units. It is possible to connect 25 contribution units to each trunk output, with a maximum system cable length of 109.3 yards (100m). Provides Control for up to 150 Contribution Units Up to 3 CUs can be used together in a discussion system to power and control a maximum of 150 contribution units. In this configuration a single CU acts as a master controller for the entire system. Built-in Monitor Loudspeaker The built-in monitor loudspeaker and headphone socket allow the conference to be monitored. Interfaces the System With External Equipment The following equipment can be interfaced to the CCS Ultro Discussion System through the CU: • External wired or wireless microphone - for guest speakers or audience participation. (Note: The external microphone is muted when the priority button on a chairman unit is pressed, and when the system is operating in 'chairman only' mode) • External PA system - for transmitting the proceedings to an audience in the same room or an adjacent room• Tape recorder - for external recording and playing back meetings and discussions • Audio equipment - for providing background music • Telephone coupler - to allow a remote delegate to participate via telephone• External audio processing - an insertion connector is provided Controls and Indicators (Top) • Mains on/off switch • Graphical display for status information (CCS‐CURD) • 5 soft buttons for configuration and control of thebuilt-in MP3 recorder (CCS‐CURD) • Loudspeaker volume control, for setting output level of loudspeakers of contribution units. This control also determines the maximum level for the headphone outputs of the contribution units and the CU. • Microphone mode rotary switch, for setting the number of simultaneously active microphones, and selecting one of the four operation modes (plus test mode) • Power on LED Controls and Indicators (Back) • On/off switch for digital acoustic feedback suppression facility (CCS‐CUD, CCS‐CURD)• Microphone input gain adjustment • External recorder input gain adjustment• Insertion connector bypass switch   Specifications: Connections Top • 1x 0.14" (3.5mm) stereo headphone socket Back • 1x AC input • 2x 7-pole circular female connectors, trunk in/out loop through interconnection  • 1x 3-pole female XLR connector, microphone input (can be used as line input by included 50dB attenuator) • 1 x Cinch connector pair, line input/output  • 1 x Cinch connector pair, telephone input/output • 1 x Cinch connector pair, insertion input/output  • 2 x Cinch connector pairs (R/L channel), external recorder input/output • USB interface (CCS-CURD) Power Supply Mains voltage: 100 to 240 VAC ± 10% Current consumption: maximum 0.9A (100 VAC) to 0.3 A (240 VAC) DC supply to contribution units: 24V ± 1V (current limited) Volume mute (50dB att.) + 10 steps of 1.9dB Limiter 10dB above nominal level loudspeaker / headphone Gain Gain reduction due to number of open microphones (NOM): ÷ NOM ± 1 dB Total Harmonic Distortion Nominal input (85 dB SPL): Max. input (110 dB SPL): Sample Rate Recording: 32kHz Playback: 32, 44.1, 48kHz Bit Rate Recording: 64, 96, 128, 192, 256 KBit/sec Playback: any bitrate Mount Tabletop (portable or fixed) 19-inch rack flush mounting Material Top: polymer Bottom: painted metal Color Charcoal and Black Dimensions (HxWxD) 3.4 x 14.2 x 5.6" (84 x 361 x 143mm) Height of feet: 0.22" (5.5mm) Weight 3.3 lb (1.5kg)
See product
Pakistan (All cities)
Description: Details iShopping.pk brings you the best price for Bosch CCS-CUD Control Unit For CCS 900 Ultro Conference System with express shipping all over Pakistan.   The Bosch CCS-CUD Control Unit is the central power and control station for all CCS 900 Ultro Conference System contributor units, such as the chairman and delegate units. The control unit will supply power for up to 50 delegate / chairman units, and provide control for up to 150. The unit features a built in speaker and automated, programmable control over contributor units without the need for an operator. Its Digital Acoustic Feedback Suppression (DAFS) eliminates feedback howling and maintains clear, intelligible speech. Plenty of connections allow for interfacing within paging systems, amplifier systems, recording devices and more. The unit is feature rich, however its control section is straightforward and intuitive to operate in any conference setting.   Features: Digital Acoustic Feedback Suppression The digital acoustic feedback suppression facility automatically eliminates acoustic feedback (also known as 'howling' or 'Larsen effect'). This gives better speech intelligibility by allowing the speaker volume to be turned up as loud as required without any risk of feedback. Discussion Control Without Operator The CU can be setup to operate standalone without the need for an operator. The following 5 modes can be chosen using a rotary control on the unit's top panel: • Open mode - allows selection of one to four microphones (excluded chairmen microphones) which can be simultaneously active • Open mode with auto-switch-off - allows selection of one to four microphones (excluded chairmen microphones) which can be simultaneously active. If the delegate does not speak for 30 seconds, microphones are automatically switched off • Override mode - delegates can override each other simply by activating their microphones. Only one microphone can be active at any one time. (Note: In override mode, delegates cannot override chairmen) • Chairman only mode - only chairmen can speak. Delegate microphones cannot be activated, even when a chairman is not speaking • Test mode - checks if system connections are correct. All microphone light rings and contribution unit LEDs light up to indicate that units are properly connected Supplies Power for up to 50 Contribution Units The CU has two trunk outputs for the loop-through connection of contribution units. It is possible to connect 25 contribution units to each trunk output, with a maximum system cable length of 109.3 yards (100m). Provides Control for up to 150 Contribution Units Up to 3 CUs can be used together in a discussion system to power and control a maximum of 150 contribution units. In this configuration a single CU acts as a master controller for the entire system. Built-in Monitor Loudspeaker The built-in monitor loudspeaker and headphone socket allow the conference to be monitored. Interfaces the System With External Equipment The following equipment can be interfaced to the CCS Ultro Discussion System through the CU: • External wired or wireless microphone - for guest speakers or audience participation. (Note: The external microphone is muted when the priority button on a chairman unit is pressed, and when the system is operating in 'chairman only' mode) • External PA system - for transmitting the proceedings to an audience in the same room or an adjacent room• Tape recorder - for external recording and playing back meetings and discussions • Audio equipment - for providing background music • Telephone coupler - to allow a remote delegate to participate via telephone• External audio processing - an insertion connector is provided Controls and Indicators (Top) • Mains on/off switch • Graphical display for status information (CCS‐CURD) • 5 soft buttons for configuration and control of thebuilt-in MP3 recorder (CCS‐CURD) • Loudspeaker volume control, for setting output level of loudspeakers of contribution units. This control also determines the maximum level for the headphone outputs of the contribution units and the CU. • Microphone mode rotary switch, for setting the number of simultaneously active microphones, and selecting one of the four operation modes (plus test mode) • Power on LED Controls and Indicators (Back) • On/off switch for digital acoustic feedback suppression facility (CCS‐CUD, CCS‐CURD)• Microphone input gain adjustment • External recorder input gain adjustment• Insertion connector bypass switch   Specifications: Connections Top • 1x 0.14" (3.5mm) stereo headphone socket Back • 1x AC input • 2x 7-pole circular female connectors, trunk in/out loop through interconnection  • 1x 3-pole female XLR connector, microphone input (can be used as line input by included 50dB attenuator) • 1 x Cinch connector pair, line input/output  • 1 x Cinch connector pair, telephone input/output • 1 x Cinch connector pair, insertion input/output  • 2 x Cinch connector pairs (R/L channel), external recorder input/output • USB interface (CCS-CURD) Power Supply Mains voltage: 100 to 240 VAC ± 10% Current consumption: maximum 0.9A (100 VAC) to 0.3 A (240 VAC) DC supply to contribution units: 24V ± 1V (current limited) Volume mute (50dB att.) + 10 steps of 1.9dB Limiter 10dB above nominal level loudspeaker / headphone Gain Gain reduction due to number of open microphones (NOM): ÷ NOM ± 1 dB Total Harmonic Distortion Nominal input (85 dB SPL): Max. input (110 dB SPL): Sample Rate Recording: 32kHz Playback: 32, 44.1, 48kHz Bit Rate Recording: 64, 96, 128, 192, 256 KBit/sec Playback: any bitrate Mount Tabletop (portable or fixed) 19-inch rack flush mounting Material Top: polymer Bottom: painted metal Color Charcoal and Black Dimensions (HxWxD) 3.4 x 14.2 x 5.6" (84 x 361 x 143mm) Height of feet: 0.22" (5.5mm) Weight 3.3 lb (1.5kg)
See product
Pakistan (All cities)
Description: Details iShopping.pk brings you the best price for Bosch CCS-CU Control Unit For CCS 900 Ultro Conference System U.S. Version with express shipping all over Pakistan.   The Bosch CCS-CU Control Unit is the central power and control station for all CCS 900 Ultro Conference System contributor units, such as the chairman and delegate units. The control unit will supply power for up to 50 delegate / chairman units, and provide control for up to 150. The unit features a built in speaker and automated, programmable control over contributor units without the need for an operator. Its Digital Acoustic Feedback Suppression (DAFS) eliminates feedback howling and maintains clear, intelligible speech. Plenty of connections allow for interfacing within paging systems, amplifier systems, recording devices and more. The unit is feature rich, however its control section is straightforward and intuitive to operate in any conference setting.   Features: Discussion Control Without Operator The CU can be setup to operate standalone without the need for an operator. The following 5 modes can be chosen using a rotary control on the unit's top panel: • Open mode - allows selection of one to four microphones (excluded chairmen microphones) which can be simultaneously active • Open mode with auto-switch-off - allows selection of one to four microphones (excluded chairmen microphones) which can be simultaneously active. If the delegate does not speak for 30 seconds, microphones are automatically switched off • Override mode - delegates can override each other simply by activating their microphones. Only one microphone can be active at any one time. (Note: In override mode, delegates cannot override chairmen) • Chairman only mode - only chairmen can speak. Delegate microphones cannot be activated, even when a chairman is not speaking • Test mode - checks if system connections are correct. All microphone light rings and contribution unit LEDs light up to indicate that units are properly connected Supplies Power for up to 50 Contribution Units The CU has two trunk outputs for the loop-through connection of contribution units. It is possible to connect 25 contribution units to each trunk output, with a maximum system cable length of 109.3 yards (100m). Provides Control for up to 150 Contribution Units Up to 3 CUs can be used together in a discussion system to power and control a maximum of 150 contribution units. In this configuration a single CU acts as a master controller for the entire system. Built-in Monitor Loudspeaker The built-in monitor loudspeaker and headphone socket allow the conference to be monitored. Interfaces the System With External Equipment The following equipment can be interfaced to the CCS Ultro Discussion System through the CU: • External wired or wireless microphone - for guest speakers or audience participation. (Note: The external microphone is muted when the priority button on a chairman unit is pressed, and when the system is operating in 'chairman only' mode) • External PA system - for transmitting the proceedings to an audience in the same room or an adjacent room • Tape recorder - for external recording and playing back meetings and discussions • Audio equipment - for providing background music • Telephone coupler - to allow a remote delegate to participate via telephone• External audio processing - an insertion connector is provided Controls and Indicators (Top) • Mains on/off switch • Graphical display for status information (CCS‐CURD) • 5 soft buttons for configuration and control of thebuilt-in MP3 recorder (CCS‐CURD) • Loudspeaker volume control, for setting output level of loudspeakers of contribution units. This control also determines the maximum level for the headphone outputs of the contribution units and the CU. • Microphone mode rotary switch, for setting the number of simultaneously active microphones, and selecting one of the four operation modes (plus test mode) • Power on LED Controls and Indicators (Back) • On/off switch for digital acoustic feedback suppression facility (CCS‐CUD, CCS‐CURD)• Microphone input gain adjustment • External recorder input gain adjustment • Insertion connector bypass switch   Specifications: Connections Top • 1x 0.14" (3.5mm) stereo headphone socket Back • 1x AC input • 2x 7-pole circular female connectors, trunk in/out loop through interconnection  • 1x 3-pole female XLR connector, microphone input (can be used as line input by included 50dB attenuator) • 1 x Cinch connector pair, line input/output  • 1 x Cinch connector pair, telephone input/output • 1 x Cinch connector pair, insertion input/output  • 2 x Cinch connector pairs (R/L channel), external recorder input/output • USB interface (CCS-CURD) Power Supply Mains voltage: 100 to 240 VAC ± 10% Current consumption: maximum 0.9A (100 VAC) to 0.3 A (240 VAC) DC supply to contribution units: 24V ± 1V (current limited) Volume mute (50dB att.) + 10 steps of 1.9dB Limiter 10dB above nominal level loudspeaker / headphone Gain Gain reduction due to number of open microphones (NOM): ÷ NOM ± 1 dB Total Harmonic Distortion Nominal input (85 dB SPL): Max. input (110 dB SPL): Sample Rate Recording: 32kHz Playback: 32, 44.1, 48kHz Bit Rate Recording: 64, 96, 128, 192, 256 KBit/sec Playback: any bitrate Mount Tabletop (portable or fixed) 19-inch rack flush mounting Material Top: polymer Bottom: painted metal Color Charcoal and Black Dimensions (HxWxD) 3.4 x 14.2 x 5.6" (84 x 361 x 143mm) Height of feet: 0.22" (5.5mm) Weight 3.3 lb (1.5kg)
See product
Pakistan (All cities)
Description: Details iShopping.pk brings you the best price for Bosch CCS-CUD Control Unit For CCS 900 Ultro Conference System U.S. Version with express shipping all over Pakistan.   The Bosch CCS-CUD Control Unit is the central power and control station for all CCS 900 Ultro Conference System contributor units, such as the chairman and delegate units. The control unit will supply power for up to 50 delegate / chairman units, and provide control for up to 150. The unit features a built in speaker and automated, programmable control over contributor units without the need for an operator. Its Digital Acoustic Feedback Suppression (DAFS) eliminates feedback howling and maintains clear, intelligible speech. Plenty of connections allow for interfacing within paging systems, amplifier systems, recording devices and more. The unit is feature rich, however its control section is straightforward and intuitive to operate in any conference setting.   Features: Digital Acoustic Feedback Suppression The digital acoustic feedback suppression facility automatically eliminates acoustic feedback (also known as 'howling' or 'Larsen effect'). This gives better speech intelligibility by allowing the speaker volume to be turned up as loud as required without any risk of feedback. Discussion Control Without Operator The CU can be setup to operate standalone without the need for an operator. The following 5 modes can be chosen using a rotary control on the unit's top panel: • Open mode - allows selection of one to four microphones (excluded chairmen microphones) which can be simultaneously active • Open mode with auto-switch-off - allows selection of one to four microphones (excluded chairmen microphones) which can be simultaneously active. If the delegate does not speak for 30 seconds, microphones are automatically switched off • Override mode - delegates can override each other simply by activating their microphones. Only one microphone can be active at any one time. (Note: In override mode, delegates cannot override chairmen) • Chairman only mode - only chairmen can speak. Delegate microphones cannot be activated, even when a chairman is not speaking • Test mode - checks if system connections are correct. All microphone light rings and contribution unit LEDs light up to indicate that units are properly connected Supplies Power for up to 50 Contribution Units The CU has two trunk outputs for the loop-through connection of contribution units. It is possible to connect 25 contribution units to each trunk output, with a maximum system cable length of 109.3 yards (100m). Provides Control for up to 150 Contribution Units Up to 3 CUs can be used together in a discussion system to power and control a maximum of 150 contribution units. In this configuration a single CU acts as a master controller for the entire system. Built-in Monitor Loudspeaker The built-in monitor loudspeaker and headphone socket allow the conference to be monitored. Interfaces the System With External Equipment The following equipment can be interfaced to the CCS Ultro Discussion System through the CU: • External wired or wireless microphone - for guest speakers or audience participation. (Note: The external microphone is muted when the priority button on a chairman unit is pressed, and when the system is operating in 'chairman only' mode) • External PA system - for transmitting the proceedings to an audience in the same room or an adjacent room • Tape recorder - for external recording and playing back meetings and discussions • Audio equipment - for providing background music • Telephone coupler - to allow a remote delegate to participate via telephone• External audio processing - an insertion connector is provided Controls and Indicators (Top) • Mains on/off switch • Graphical display for status information (CCS‐CURD) • 5 soft buttons for configuration and control of thebuilt-in MP3 recorder (CCS‐CURD) • Loudspeaker volume control, for setting output level of loudspeakers of contribution units. This control also determines the maximum level for the headphone outputs of the contribution units and the CU. • Microphone mode rotary switch, for setting the number of simultaneously active microphones, and selecting one of the four operation modes (plus test mode) • Power on LED Controls and Indicators (Back) • On/off switch for digital acoustic feedback suppression facility (CCS‐CUD, CCS‐CURD)• Microphone input gain adjustment • External recorder input gain adjustment • Insertion connector bypass switch   Specifications: Connections Top • 1x 0.14" (3.5mm) stereo headphone socket Back • 1x AC input • 2x 7-pole circular female connectors, trunk in/out loop through interconnection  • 1x 3-pole female XLR connector, microphone input (can be used as line input by included 50dB attenuator) • 1 x Cinch connector pair, line input/output  • 1 x Cinch connector pair, telephone input/output • 1 x Cinch connector pair, insertion input/output  • 2 x Cinch connector pairs (R/L channel), external recorder input/output • USB interface (CCS-CURD) Power Supply Mains voltage: 100 to 240 VAC ± 10% Current consumption: maximum 0.9A (100 VAC) to 0.3 A (240 VAC) DC supply to contribution units: 24V ± 1V (current limited) Volume mute (50dB att.) + 10 steps of 1.9dB Limiter 10dB above nominal level loudspeaker / headphone Gain Gain reduction due to number of open microphones (NOM): ÷ NOM ± 1 dB Total Harmonic Distortion Nominal input (85 dB SPL): Max. input (110 dB SPL): Sample Rate Recording: 32kHz Playback: 32, 44.1, 48kHz Bit Rate Recording: 64, 96, 128, 192, 256 KBit/sec Playback: any bitrate Mount Tabletop (portable or fixed) 19-inch rack flush mounting Material Top: polymer Bottom: painted metal Color Charcoal and Black Dimensions (HxWxD) 3.4 x 14.2 x 5.6" (84 x 361 x 143mm) Height of feet: 0.22" (5.5mm) Weight 3.3 lb (1.5kg)
See product
Pakistan (All cities)
Description: Details iShopping.pk brings you the best price for Shure Central Control Unit With Power Supply Kit with express shipping all over Pakistan.   The Central Control Unit for DDS 5900 and DCS 6000 Conference Systems from Shure powers up to 60 microphone units and supports up to 250 units. It supports 2 languages and 32 interpreters and can be used in various speech-application environments such as hotel/conference centers, multi-purpose/training rooms, education facilities, corporate/board rooms, courtrooms, and more. Featuring two analog audio inputs for external sources, the Central Control Unit has eight analog audio outputs for connections to videoconferencing systems, A/V recording equipment, supplemental sound reinforcement systems, or wireless language distributions system. In addition, with Feature License FL6000 (sold separately), the DIS-CCU can be used with DCS 6000-series microphone units serving up to 250 participants and 4 languages. Additional Feature Licenses enable support for up to 3,800 participants, 200 interpreters, and 31 languages. • Fully digital audio transmission of floor plus 31 interpretation channels and 8 conference microphone audio channels in a single digital-bus cable structure using shielded CAT5e cables • OLED display on the front enables the user to setup basic system configurations in terms of maximum number of speakers/requests, microphone operation mode, etc. • TCP/IP Ethernet connection for web browser control, integration with optional SW 6000 software suite, or third party external control system (AMX, Crestron, etc.) • 2 analog audio inputs and 8 analog audio outputs for distribution of audio from eight groups of units, the floor channel, or the interpreter channels. • Connection for Emergency Evacuation Message (EEM) is available using 'Audio In 2' and a contact closure switch • Powers up to 60 units without additional power supply (depending on unit type)   Features: • Central Control Unit and Microprocessor • Power Supply for Central Control Unit • For DDS 5900 & DCS 6000 Systems • 4 Modes: Auto, FIFI, VOX, and Manual • 3 Microphone Interrupt Modes • 2 Analog Audio Inputs • Up to 8 Microphones Open at One Time • Scrambles Audio to Avoid Evesdropping • Auto Off of Conference Units   Specifications: System Performance Max Number of Discussion Units For DDS 5900: 250 Powered by CU 5905: 60 Microphones Max Number Open: 8 Languages Interpreter Channels: 2 Max Number of Interpreter Units: 32 Network LAN DCS-LAN Outputs: 4 x RJ45 female sockets TCP/IP 1 x RJ45 female socket Audio Inputs Analog Input 1: 1 x 3-pin female XLR socket (electronically balanced) Analog Input 2 EEM: 1 x 3-pin female XLR socket (electronically balanced) with contact closure Input Level Max: +15 dBm (4.5 Vrms) Input Impedance 50 to 100 kOhms Audio Output 8 x 3-pin XLR (electronically balanced) Maximum load: >1 kOhms Maximum Load >1 kOhms Nominal Output Levels 0 dBm at nominal input Maximum Output Level 4.9 Vrms ~ +16 dBm Electrical Power Consumption 22 W/48 V (150 W max.) Supply Voltage For Microphone Units: 122 W/48 V Sampling Frequency 24-bit/32 kHz Total Harmonic Distortion (THD) Signal to Noise Ratio >85 dBA Mechanical Mounting Tabletop, standard 19" rack. Storage Temperature Range -4 to 140°F (-20 to 60°C) Operating Temperature Range 41 to 104°F (5 to 40°C) Humidity 10 to 80% Dimensions (H x W x D) 1.75 x 16.8 x 7.2" (44.4 x 426 x 186 mm) Weight 6.17 lb (2.8 kg)  
See product
Pakistan (All cities)
Product Description           What This Product Does The TL-SG1008PE is an 8-port gigabit desktop/rack mountable switch with all 8 ports supporting the PoE+ standard. These PoE ports can automatically detect and supply power to those IEEE 802.3af/at compliant Powered Devices (PDs). In this situation, the electrical power is transmitted along with data in one single cable, allowing you to expand your network to where there are no power outlets and you wish to fix devices such as APs, IP Cameras or IP Phones, etc. Key Features 8 PoE Ports Equipped with 8 PoE ports with a total power budget of 124W, the TL-SG1008P can power up to eight 802.3af/at PoE compliant devices such as IP cameras, IP telephones or wireless access points. By delivering power over Ethernet, the TL-SG1008PE allows for flexible placement of network devices and eliminates the trouble and cost of extra wiring. Port Priority Protects Your Investment The priority of supplying power goes down from Port 1 to Port 8. This function will help protecting the system when system power becomes overloaded. For example, if port 1, 2, 4 and 7 are using 30W (maximum power per port is 30W), then the total power is 120W. And if there is an additional device inserted into port 3 at 25W, the system will cut off the power of port 7. As a result, port 1, 2 and 4 will use 30W, and port 3 will use 25W. No power will be supplied to port 7. Power Saving of up to 75% The TL-SG1008PE features innovative energy-efficient technologies that can automatically reduce power consumption by up to 75%. Diagnostic LED Indicators Diagnostic LED lights on the front panel display the information of power, link/activity, and speed - allowing you to quickly detect and correct problems on the network.      
Rs 16.599
See product
Pakistan (All cities)
D-Link DGS-1016D 16-Port 10/100/1000 Switch Get the blazing speed of Gigabit Ethernet with the DGS-1016D 16-Port 10/100/1000 Switch from D-Link, a 16-port 10/100/1000Mb/s switch that delivers power, performance and reliability in one cost-effective, space-saving design. Increase the speed of your network server and backbone connections, or make Gigabit to the desktop a reality. Power users in the office or creative production environment can now move large, bandwidth-intensive files faster. Transfer graphics, CGI, CAD, or multimedia files across the network near instantly. This switch features D-Link Green eco-friendly technology, which reduces power consumption and operating costs, all in a desktop or rack mountable design. Easy To Use The auto features of the DGS-1016D make installation plug-and-play and hassle-free; no configuration required! Auto MDI/MDI-X crossover on all ports eliminate the need for crossover cables or uplink ports. Auto-negotiation on each port senses the link speed of a network device (10, 100 or 1000Mb/s) and intelligently adjusts for optimal performance. The DGS-1016D also features diagnostic LEDs which display status and activity, allowing you to quickly detect and correct problems on the network. Every port also supports a cable diagnostic feature that helps to detect cable related issues. Power-Packed It features a non-blocking switching architecture that filters and forwards packets at full wire-speed for maximum throughput. An 8K MAC address table provides scalability for even the largest networks. Address learning and aging, 802.3x Flow Control for full-duplex mode, and back pressure flow control for half-duplex mode alleviates traffic congestion and ensures reliable data transmission. Designed using industry standards, the DGS-1016D is compatible with virtually all 10, 100 and 1000Mb/s Ethernet devices and other vendor equipment. The 16-Port 10/100/1000 Switch protects your existing network investments while providing you with a straightforward migration path to faster Gigabit speeds. Power Savings by Number of Connected Ports and Link Status Computers do not require Internet access all the time; neither do switches utilize all ports at all times. When a computer or network equipment is shut down, switches often remain on and continue to consume considerable amounts of power. With D-Link Green Technology, D-Link switches can automatically detect link status and reduce power usage of ports that are idle. Computers or any connecting parties set to standby mode (not power off), however, will not provide significant power savings. Power Savings by Cable Length D-Link Green verified switches have the ability to analyze the length of any Ethernet cable connected to them for adjustment of power usage accordingly. Shorter lengths require less power. Overall Power Savings Per Day For a traditional switch, power consumption remains constant even when the ports are not in use. In a standard workday scenario where PCs are used for 10 hours a day and powered off 14 hours a day, and connected to the switch using 20 meter cables, D-Link Green Technology can save up to 20% power used for each system. Specs   Protocols Transmission Method Store-and-Forward MAC Address Table Size 8K Standards Supported IEEE Standards 802.1p, 802.3, 802.3ab, 802.3u, 802.3x Performance Switching Bandwidth 32 Gb/s  Priority Queues 4 Packet Buffer 512 Kb Electrical AC Input Power 100 to 240 VAC, 50 / 60 Hz Power Supply Type Internal Environmental Operating Temperature 32 to 104°F / 0 to 40°C Operating Humidity 5 to 95% Storage Temperature 14 to 131°F / -10 to 55°C General Indicator Lights Link/Activity, Power, Speed Dimensions 11 x 7.1 x 1.7" / 28 x 18 x 4.4 cm Weight 4 lb / 2 kg
Rs 10.000
See product

Free Classified ads - buy and sell cheap items in Pakistan | CLASF - copyright ©2024 www.clasf.pk.