Automatic mains
Top sales list automatic mains
Pakistan (All cities)
DESCRIPTION Output Max Configurable Power (Watts) 3.5kWatts / 5.0kVA Output Voltage Note Configurable for 208 or 240 nominal output voltage Output Voltage Distortion Less than 3 % Output Frequency (sync to mains) 50/60 Hz +/- 3 Hz user adjustable +/- 0.1 Hz Sync to mains Other Output Voltages 240 V Load Crest Factor 3: 1 Topology Double conversion online Waveform type Sine wave Bypass Internal bypass (automatic and manual) Input Input frequency 50/60 Hz +/- 5 Hz Auto-sensing Input voltage range for main operations 160 - 280, Adjustable (half load)V Number of Power Cords 1 Other Input Voltages 240 V Batteries & Runtime Battery type Lead-acid battery Included Battery Modules 2 Typical recharge time 2.5hour(s) Replacement Battery APCRBC140 Expected Battery Life (years) 3 - 5 RBC Quantity 1 Battery Charge Power (Watts) 382 Watts Extendable Run Time 1 Runtime View Runtime Graph Efficiency View Efficiency Graph Communications & Management Interface Port(s) RJ-45 10/100 Base-T, RJ-45 Serial, SmartSlot Pre-Installed SmartSlot™ Cards AP9631 Control panel LED status display with load and battery bar-graphs and on line: on battery: replace battery: overload and bypass indicators Audible Alarm Alarm when on battery: distinctive low battery alarm: overload continuous tone alarm Emergency Power Off (EPO) Yes Surge Protection and Filtering Surge energy rating 555Joules 2 year warranty repair or replace Mention that you found this ad on DealMarkaz.pk when you call.
See product
Pakistan (All cities)
DESCRIPTION APC UPS 3KVA ONLINE FOR MEDICAL MACHINERY IT HOME DATA CENTER Output Max Configurable Power (Watts) 2.1kWatts / 3.0kVA Output Voltage Note Configurable for 220: 230 or 240 nominal output voltage Efficiency at Full Load 91.0 % Output Voltage Distortion Less than 3 % Output Frequency (sync to mains) 50/60 Hz +/- 3 Hz user adjustable +/- 0.1 Hz Sync to mains Other Output Voltages 220 V, 240 V Load Crest Factor 3: 1 Topology Double conversion online Waveform type Sine wave Bypass Internal bypass (automatic and manual) Input Input frequency 50/60 Hz +/- 5 Hz Auto-sensing Input voltage range for main operations 100 - 280 Adjustable, 160 - 280V Number of Power Cords 1 Efficiency at Full Load 91.0 % Other Input Voltages 220 V, 240 V Batteries & Runtime Battery type Lead-acid battery Included Battery Modules 2 Typical recharge time 2.5hour(s) Expected Battery Life (years) 3 - 5 RBC Quantity 1 Battery Charge Power (Watts) 382 Watts Extendable Run Time 1 Runtime View Runtime Graph Communications & Management Interface Port(s) DB-25 RS-232, Smart-Slot Control panel LED status display with load and battery bar-graphs and on line: on battery: replace battery: overload and bypass indicators Audible Alarm Alarm when on battery: distinctive low battery alarm: overload continuous tone alarm Emergency Power Off (EPO) Yes Available SmartSlot™ Interface Quantity 1 Surge Protection and Filtering Surge energy rating 480Joules Filtering Full time multi-pole noise filtering: 0.3% IEEE surge let-through: zero clamping response time: meets UL 1449 Physical Maximum Height 432MM, 43.2CM Maximum Width 130MM, 13.0CM Maximum Depth 660MM, 66.0CM Net Weight 54.56KG Shipping weight 63.64KG Shipping Height 347MM, 34.7CM Shipping Width 603MM, 60.3CM Shipping Depth 980MM, 98.0CM Color Black Units per Pallet 6.0 Environmental Operating Temperature 0 - 40 °C Operating Relative Humidity 0 - 95 % Operating Elevation 0 - 3048meters Storage Temperature -15 - 45 °C Storage Relative Humidity 0 - 95 % Storage Elevation 0 - 15240meters Audible noise at 1 meter from surface of unit 55.0dBA Online thermal dissipation 655.0BTU/hr Conformance Approvals BSMI, C-Tick, CE, CSA, EN 50091-1, EN 50091-2, EN 55022 class A, EN 60950, EN 61000-3-2, GOST, JEON, UL 1778, VCCI, VDE Standard warranty 2 years repair or replace Mention that you found this ad on DealMarkaz.pk when you call.
See product
Karachi (Sindh)
Product Description 5 kW Beautiful Touch Screen Display 2 outputs for Automatic load management along with the online monitoring device Battery in-dependency (can work without battery) Compatible with K-Electric mains Parallel Operation up to 9 Units We are Authorize Distributor of Tesla Solar, Inverex, Maxpower Off Grid and Hybrid Solar Inverters We also deal in Axpert Voltronics MKS, VMII, VMIII, Infini V, INFINITY HLE, Aerox Series and Nitrox. For More Information Contact Now Special Discount for wholesalers *Stock Availble*
See product
Pakistan (All cities)
Output Output Power Capacity 12.8 kW / 16 kVA Max Configurable Power 12.8 kW / 16 kVA Nominal Output Voltage 120V,208V Output Voltage Note Configurable for 120/208 or 120/240 output voltage Output Voltage Distortion Less than 5% at full load Output Frequency (sync to mains) 47 - 63 Hz Crest Factor up to 5: 1 Waveform Type Sine wave Output Connections (1) Hard Wire 4-wire (2PH + N +G) Bypass Internal Bypass (Automatic and Manual) Input Nominal Input Voltage 208V Input Frequency 45 - 65 Hz (auto sensing) Input Connections Hard Wire 4-wire (2PH+N+G) Input voltage range for main operations 96 - 138 (Line to Neutral)V Other Input Voltages 240V Batteries & Runtime Battery Type Maintenance-free sealed Lead-Acid battery with suspended electrolyte: leakproof Included Battery Modules 4 Typical recharge time 3 hour(s) Replacement Battery SYBT5 Typical Backup Time at Half Load 17.1 minutes (6400 Watts) Typical Backup Time at Full Load 6.0 minutes (12800 Watts) Runtime Chart Symmetra LX
Rs 180.000
See product
Pakistan (All cities)
DESCRIPTION Physical number of rack unit 6U colour Black depth 73.6 cm height 43.2 cm mounting location Front mounting preference Lower product weight 110.91 kg mounting mode Not rack-mountable two post mountable 0 USB compatible No width 26.3 cm INPUT network frequency 50/60 Hz +/- 5 Hz auto-sensing number of input connectors 1 hard wire 3-wire (1P + N + E) 1 hard wire 5-wire (3P + N + Einput voltage limits 160...280 V inputvolt_other 220 V 240 V input harmonic distortion Less than 7 % for full load input voltage 230 V 400 V 3 phases OutputOutput rated power in W 8000 W Maximum configurable power in W 8000 W harmonic distortion Less than 3 % output frequency 50/60 Hz +/- 3 Hz user adjustable +/- 0.1 Hz sync to mains Output voltage 220 V 240 V crest factor 3: 1 UPS type Double conversion online Wave type Sine wave output connector type Hard wire 3-wire (H N + E) 1 nb of power socket outlets 4 IEC 60320 C13 6 IEC Jumpers 4 IEC 60320 C19 bypass type Internal bypass (automatic and manual)curve load maximum 100 % curve load minimum 3 % curve proportional loss 0.0304 curve square loss 0.038 curve X-axis maximum 100 % curve test cond ID Curve fit to measured efficiency data. All measurements taken in normal operating mode, at typical environmental conditions, with nominal electrical input and balanced resistive load (PF = 1.0) output. curve X-axis minimum 0 % curve X-axis title Load curve X-axis units Percentage curve Y-axis maximum 100 % curve Y-axis minimum 50 % curve Y-axis title Efficiency curve Y-axis units Percentage graph display 1 output voltage 230 V Maximum configurable power in VA 10000 VA rated power in VA 10000 VA Conformance product certifications C-Tick CE GOST VDE 1 year replace or repair warranty Mention that you found this ad on DealMarkaz.pk when you call.
See product
Pakistan (All cities)
DESCRIPTION Product Description 5 kW Beautiful Touch Screen Display 2 outputs for Automatic load management along with the online monitoring device Battery in-dependency (can work without battery) Compatible with K-Electric mains Parallel Operation up to 9 Units We are Authorize Distributor of Tesla Solar, Inverex, Maxpower Off Grid and Hybrid Solar Inverters We also deal in Axpert Voltronics MKS, VMII, VMIII, Infini V, INFINITY HLE, Aerox Series and Nitrox. For More Information Contact Now Special Discount for wholesalers *Stock Availble* Mention that you found this ad on DealMarkaz.pk when you call.
See product